1.Application |
| |
JR29 series thermal overload relay is mainly suitable for A.C.electric power system with volt-age up to 660V, current up to 500A, 50/60Hz. It is generally used for the protection of overloadand phase-lacking in circuits with three-phase induce motors and is often made up electromag-netic starters with CJX8 series A.C. contactors. The product conforms to IEC60947-4-1 stardand.Noter: JR29-16 is manually reset automatic to the other. |
| |
2. Motion Characteristic: Three-phase Balance Motion Time |
| |
| No |
Times the
setting current |
Motion time |
Start conidition |
Ambient
temperature |
|
1 |
1.05 |
>2h |
cold state |
20oC±5oC |
|
2 |
1.2 |
<2h |
heat state
(Following the No.1 test) |
|
3 |
1.5 |
<4min |
|
4 |
7.2 |
10A |
2s< TP ≤ 10S |
≤ 63A |
cold state |
|
10 |
4s< TP ≤ 10S |
≤ 63A |
|
| |
|
3.
Phase-losing Motion Characteristic |
| |
|
No |
Times the setting current |
Motion time |
Start condition |
Ambient temperature |
|
Any two phase |
Another phase |
|
1 |
1.0 |
0.9 |
>2h |
cold state |
20oC±5oC |
|
2 |
1.15 |
0 |
<2h |
heat state
(Following the No.1 test) |
|
| |
|
4.
Specification |
| |
| Type |
Setting Range(A) |
For Contactor |
|
JR29-16
|
0.11~0.16 |
CJX8-09
CJX8-16 |
|
0.14~0.21 |
|
0.19~0.29 |
|
0.27~0.4 |
|
0.35~0.52 |
|
0.42~0.63 |
|
0.55~0.83 |
|
0.7~10. |
|
0.9~1.3 |
|
1.1~1.5 |
|
1.3~1.8 |
|
1.5~2.1 |
|
1.7~2.4 |
|
2.1~3 |
|
2.7~4 |
|
3.4~4.5 |
| 4~6 |
|
5.2~7.5 |
|
6.3~9 |
|
7.5~11 |
|
9~13 |
|
12~17.6 |
|
|
| Type |
Setting Range(A) |
For Contactor |
|
JR29-25
|
0.1~0.16 |
CJX8-25
CJX8-30 |
|
0.16~0.25 |
|
0.25~0.4 |
|
0.4~0.63 |
|
0.63~1 |
|
1~1.4 |
|
1.3~1.8 |
|
1.7~2.4 |
|
2.2~3.1 |
|
2.8~4 |
|
3.5~5 |
|
4.5~6.5 |
|
6~8.5 |
|
7.5~11 |
|
10~14 |
|
13~19 |
|
18~25 |
|
24~32 |
| - |
| - |
| - |
| - |
|
|
| |
| Type |
Setting Range(A) |
For Contactor |
JR29-45 |
0.28~4 |
CJX8-37
CJX8-45 |
| 0.35~0.52 |
| 0.45~0.63 |
| 0.55~0.83 |
| 0.7~1 |
| 0.86~1.3 |
| 1.1~1.6 |
| 1.4~2.1 |
| 1.8~2.5 |
| 2.2~3.3 |
| 2.8~4 |
| 3.2~5.2 |
| 4.5~6.3 |
| 5.5~8.3 |
| 7~10 |
| 8.6~13 |
| 11~16 |
| 14~21 |
| 18~27 |
| 25~35 |
| 30~45 |
| - |
| - |
| - |
|
|
| Type |
Setting Range(A) |
For Contactor |
JR29-85
|
6~10 |
CJX8-65
CJX8-85 |
| 8~14 |
| 12~20 |
| 17~29 |
| 25~40 |
| 35~55 |
| 45~70 |
| 60~100 |
JR29-105
|
27~42 |
CJX8-105 |
| 36~52 |
| 45~63 |
| 57~82 |
| 70~105 |
| 80~115 |
JR29-170
|
90~130 |
CJX8-170 |
| 100~160 |
| 140~200 |
JR29-250
|
100~160 |
CJX8-250 |
| 160~250 |
| 250~400 |
JR29-370
|
100~160 |
CJX8-370 |
| 160~250 |
| 250~400 |
| 310~500 |
|
|
| |
5. Outline and Mounting Dimension |
|
JR29-16 Independent installation
|
|
|
JR29-25 Independent installation |
|
|
JR29-45 Independent installation |
|
|
JR29-85 Independent installation |
|
|
JR29-105 Independent installation |
|
|
JR29-250 Independent installation |
|
|
| |
6. Accessories |
| |
| Pic |
|
|
|
| Description |
JR29-16 mounting base |
JR29-25 mounting base |
JR29-75 mounting base |
| Application |
Assembled with JR29-16 to form acomplete set |
Assembled with JR29-25 to form acomplete set |
Assembled with JR29-75 to form acomplete set |
|
|